Chat with us

Replacement ESD Ground Cord – 1 MΩ Resistor, Coiled or Straight, 4mm Snap

Replacement ESD ground cord with built-in 1 MΩ resistor. Coiled (1.8m to 3m) or straight (1.8m). 4mm snap, stainless clip. Flex life tested to 15,000 cycles.

Category

We are committed to delivering five‑star service across every product we offer — from responsive support to reliable delivery and beyond. Your satisfaction is our benchmark.

This replacement ground cord is designed for ESD wrist straps with a detachable 4mm snap. It includes the required 1 MΩ current‑limiting resistor and a stainless steel alligator clip. When your original cord fails from daily flexing, replace the cord – not the entire wrist strap.

Available in two types:

  • Coiled cord – stretches from 1.8m to 3m (6–10 ft), tangle‑resistant

  • Straight cord – 1.8m (6 ft), lighter, longer flex life

Both versions use the same 4mm snap and clip, and both contain the 1 MΩ resistor.

Specifications
ParameterCoiled versionStraight version
Part numberESD‑CORD‑COIL‑6FTESD‑CORD‑STRAIGHT‑6FT
Cord length (relaxed)1.8 m (6 ft)1.8 m (6 ft)
Stretched length (max)3.0 m (10 ft)N/A (non‑stretch)
Cord jacket materialPolyurethane (PUR)PVC
Snap type4 mm nickel‑plated brass4 mm nickel‑plated brass
Clip typeStainless steel alligator with teethStainless steel alligator with teeth
Integrated resistor1 MΩ, ±5%1 MΩ, ±5%
System resistance (snap to clip)0.95 – 1.05 MΩ typical0.95 – 1.05 MΩ typical
Flex life (at snap)>15,000 cycles (tested)>25,000 cycles (tested)
Operating temperature0 – 50°C0 – 50°C
RoHS compliantYesYes
Cleanroom compatibleYes (low shedding)Yes (PVC acceptable for ISO 7+)
Real Test Data – Flex Life Comparison

We tested both cord types to failure (open circuit). Test method: 90° bend at the snap connection, 1 cycle per second.

CyclesCoiled cord (resistance)Straight cord (resistance)
0 (new)0.98 MΩ1.01 MΩ
5,0001.00 MΩ1.00 MΩ
10,0001.03 MΩ1.01 MΩ
15,0001.09 MΩ (pass)1.02 MΩ
20,000Open circuit (fail)1.03 MΩ
30,0001.08 MΩ (pass)
35,000Open circuit (fail)

Conclusion: Straight cord lasts approximately twice as long as coiled cord in flex life. Choose straight for workstations where the cord is plugged in and left; choose coiled for operators who move around and need stretch.

Customer Reviews

Our clients from semiconductor, pharmaceutical, medical device, and aerospace industries trust our cleanroom wipers for consistent performance, high absorption, and low particle generation. Here’s what they have to say.

Father giving son a ride on shoulders, both laughing and smiling in a park setting.
Johnathan Doe

Founder & CEO

Experience the stunning spring bloom in a Paris park, featuring vibrant flowers and lush greenery.
Johnathan Doe

Marketing Head

Group of adults engaging in fun team building activities in a sunny park, showcasing teamwork and diversity.
Johnathan Doe

Finance Head

We have broken down the core products and actual test data into a clear, at-a-glance comparison table across six industries (semiconductor wafers, OLED panels, precision optics, biopharmaceuticals, automotive electronics, and new energy batteries). The table includes the wiper or cleanroom consumable model for each industry, key physical parameters (particle shedding, water absorbency, ionic residues, etc.), and applicable compliance standards (SEMI, GMP, IATF 16949, ISO 10993, etc.)